Apc Backup Ups Ns1350 Users Manual

Advertising

0017

Manual APC Back-UPS 550. View the APC Back-UPS 550 manual for free or ask your question to other APC Back-UPS 550 owners. Typical backup time at half load. User Manual Back-UPS ® BE550G/BE700G Caution. For safety, the Back-UPS ES is shipped with one battery wire disconnected. Small sparks may occur during battery connection. Do not install the unit in direct sunlight, in excessive heat or humidity, or in contact with fluids.

0017

0017

0017

0017

CONNECT TVSS

Back-UPS

®

RS/XS 1200

User’s Manual

1

®

CONTENTS

RJ-45

USB

RJ-11

RJ-11

2

3

CONNECT BATTERY CARTRIDGE

OPERATING ENVIRONMENT

3

4

CONNECT EQUIPMENT / POWER

Monitor

Printer or Scanner

FAX

External Disk or
CD / DVD Drive

Input: 120V~

12A, 60Hz

Circuit Breaker

Push to Reset

SURGE ONLY

BATTERY BACKUP

Computer

5

CHECK BUILDING WIRING
FAULT INDICATOR

Building

Wiring Fault

Wall

Outlet

Modem/

Phone/Fax

TVSS GND

Building Wiring

Fault Indicator

6

Phone Jack

Computer

Modem Port

CONNECT PHONE/MODEM/FAX

TVSS GND

Wall

Outlet

Wall

Outlet

Modem/

Phone/Fax

7

CONNECT 10/100 Base-T or VOIP

Network Jack

Computer

Network Port

8

To Computer USB

Port

CONNECT INTERFACE

Data Port

BR24BP Battery Pack

Computer

11

INSTALL SOFTWARE ON
COMPUTER

There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery, Overload,
and Replace Battery).

On Line (green)

- is lit whenever utility power is

powering the Battery Backup outlets.

On Battery (yellow)

- is lit whenever the battery of

the Back-UPS is powering equipment connected to the
Battery Backup Outlets.

Four Beeps Every 30 Seconds - this alarm is
sounded whenever the Back-UPS is running On
Battery. Consider saving work in progress.

Overload (red)

- is lit whenever power demand has

exceeded the capacity of the Back-UPS.

Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.

Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the Back-
UPS to disconnect itself from utility power. If the
button sticks out, disconnect non-essential
equipment. Reset the circuit breaker by pushing
the button inward.

Replace Battery (red)

- is lit whenever the battery is

near the end of its useful life, or if the battery is not con-
nected (see above). A battery that is near the end of its use-
ful life has insufficient run-time and should be replaced.

Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has failed
the automatic diagnostic test.

Note: Allow the Back-UPS to charge for a full
eight (8) hours prior to use.

Press the front panel Power ON/OFF switch and
observe that the following events occur after
pressing and releasing the switch:

• The green On Line indicator flashes.
• The yellow On Battery indicator lights while

a Self-Test is being performed.

• When Self-Test has successfully completed,

only the green On Line indicator will be lit.

• If the internal battery cartridge is not

connected (see Step 2 above), the green On
Line indicator and red Replace Battery
indicators will light. The Back-UPS will also
emit a chirping sound.

Continuous Beeping - this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save any
work in progress and exit all open applications.
Shutdown the operating system, computer and
the Back-UPS.

If Autoplay is not enabled on the computer, proceed
as follows:

1. On the computer desktop of the display, double-

click on My Computer.

2. Double-click on the CD-ROM drive icon and

follow the on-screen instructions.

If the rear panel Building Wiring Fault (red)
indicator is lit, a potential shock hazard exists
due to one of the following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit
Improper building wiring should be
corrected by a qualified electrician. Do not
use the Back-UPS until the condition that
caused the fault is corrected.
Note
: Improper building wiring will not
prevent the Back-UPS from operating, but it
will limit its protection capability.

9

SWITCH ON THE BACK-UPS

10

ORIENTATION

12

GROUND

The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.

Wall

Outlet

Modem/

Phone/Fax

TVSS GND

From Data Line

TVSS

Follow the

on-screen

instructions.

On Line

On Battery

Overload

Replace Battery

w

w

w.apc.com

®

RJ-45

Apc Backup Ups Ns1350 Users Manual Online

USB

10/100 Base-T

VOIP

STATUS INDICATORS AND ALARMS

For connection of APC’s optional

external 24-volt battery pack

(BR24BP) to the Back-UPS RS/XS 1500.

(Back-UPS RS models only)

CABLE

32 - 104

o

F (0 - 40

o

Manual

C)

001b

0017

0017

0017

Apc Ups Manual

Back-UPS

®

RS/XS 1500

Apc Backup Ups Ns1350 Users Manual 2017